METTA electrical panels for surface pumps (main materials CHINT) are designed for the correct operation and control of the pump, ensuring at the same time its protection by means of level electrodes or float switch.
METTA surface pump panels – Main materials CHINT
METTA electrical panels for surface pumps with CHINT materials ensure the correct operation and control of the pump, protecting it through electrodes or a digital level indicator.
Category: Control Panels
Brand: METTA
START-UP PANEL FOR SURFACE PUMP 230V UP TO 2,2KW CS1D1___
- Plastic watertight cabinet of protection class IP54
- General bipolar load switch
- Automatic fuse depending on the current drawn by the pump to protect against overcurrent, short circuit
- Starter for direct starting of the pump
- Thermal relay to protect the pump from overload
- Possibility of connecting a float switch for protection against water shortage
- Level monitor for detecting water shortage with electrodes
- I-0-II selector switch for manual or automatic operation
- Contact for operation with float, push button or timer in automatic mode
- Indicator lights for operation, fault, water shortage
- Connection terminal block accompanied by wiring diagram
START-UP PANEL FOR SURFACE PUMP 400V UP TO 5,5KW CS1D3___
- Plastic watertight cabinet of protection class IP54
- General load switch
- Asymmetry, succession and out-of-phase monitor
- Thermomagnetic switch according to the current drawn by the pump to protect against overload, overcurrent, short circuit
- Starter for direct starting of the pump
- Possibility of connecting a float switch for protection against water shortage
- I-0-II selector switch for manual or automatic operation
- Contact for operation with float, push button or timer in automatic mode
- Indicator lights for operation, fault, voltage fault
- Connection terminal block accompanied by wiring diagram
START-UP PANEL FOR SURFACE PUMP 400V UP TO 5,5KW CS1Y3___
- Metal waterproof cabinet of protection class IP54
- General load switch
- Asymmetry, succession and out-of-phase monitor
- Automatic “D” curve fuses in combination with thermal relay, suitable for motor protection against overcurrent, short circuit and overload or alternatively, thermomagnetic circuit breaker
- H/D starter sized according to the pump capacity
- Possibility of connecting a float switch for protection against water shortage
- I-0-II selector switch for manual or automatic operation
- Contact for operation with float, push button or timer in automatic mode
- Indicator lights for operation, fault, voltage fault, water shortage
- Connection terminal block accompanied by wiring diagram
| CODE | ADDITIONS |
| F | Free voltage contacts for operation and fault indication (for CS1D1__ PANELS) |
| Free voltage contacts for operation, fault and voltage fault indication (for CS1D3__ and CS1Y3__ PANELS) | |
| M | 3-display instrument with voltage transformers |
| P | Protection against dry operation via drilling power factor (cosf) without Autoreset |
| Χ | Reinforced universal socket |
| Ε | LED interior lighting |
- Control and automation panels for starting a wide range of surface pumps.
- Protection against dry running of the pump in case of possible drainage of the pumping tank by means of a float switch or level electrodes.
- Start-up command via pushbutton, timer or adjustable differential level float switch with counterbalance.
| SINGLE SURFACE PUMP START-UP PANELS | ||||||||
| Type | Voltage | Hp | KW | Start-up | Range A | Box material | Protection | Dimensions H x W x D (mm) |
| CS1D1007 | 230V | 1 | 0,75 | DOL | 4-6 | ABS | IP54 |
400x300x170 |
| CS1D1011 | 1,5 | 1,1 | 5,5-8 | 400x300x170 | ||||
| CS1D1015 | 2 | 1,5 | 7-10 | 400x300x170 | ||||
| CS1D1022 | 3 | 2,2 | 9-13 | 400x300x170 | ||||
| CS1D3007 | 400V | 1 | 0,75 | DOL | 1,6-2,5 |
ABS
|
IP54
|
400x300x170 |
| CS1D3011 | 1,5 | 1,1 | 1,6-2,5 | 400x300x170 | ||||
| CS1D3015 | 2 | 1,5 | 2,5-4 | 400x300x170 | ||||
| CS1D3022 | 3 | 2,2 | 4-6,3 | 400x300x170 | ||||
| CS1D3030 | 4 | 3 | 6-10 | 400x300x170 | ||||
| CS1D3040 | 5,5 | 4 | 6-10 | 400x300x170 | ||||
| CS1Υ3055 | 400V | 7,5 | 5,5 |
Υ/Δ
|
9-14* |
METAL
|
IP54
|
500x400x200 |
| CS1Υ3075 | 10 | 7,5 | 13-18* | 500x400x200 | ||||
| CS1Υ3110 | 15 | 11 | 20-25* | 600x400x200 | ||||
| CS1Υ3150 | 20 | 15 | 21-29 | 600x400x200 | ||||
| CS1Υ3185 | 25 | 18,5 | 30-36 | 700x500x200 | ||||
| CS1Υ3220 | 30 | 22 | 30-43 | 700x500x200 | ||||
| CS1Υ3300 | 40 | 30 | 40-55 | 800x600x200 | ||||
| CB1Υ3370 | 50 | 37 | 52-69 | 800x600x200 | ||||
In the CS1Y3__ series a fuse with a thermal switch is used except for the asterisks where a thermomagnetic one is used.
- Construction with CHINT main materials