METTA electrical panels for sewage pumps are designed for proper operation and protection of the pump, providing at the same time the possibility of full autonomy in control through start-stop float switches.
METTA sewage pump starting panels – Main materials CHINT
METTA electrical panels for sewage pump starting with ABB materials, ensure the correct operation and control of the pump, protecting it through electrodes or digital level indicator.
Category: Control Panels
Brand: METTA
START-UP PANEL FOR SINGLE-PHASE WASTEWATER PUMP CD1D1___
- Plastic watertight cabinet of protection class IP54
- General bipolar load switch
- Automatic fuse depending on the current drawn by the pump to protect against overcurrent, short circuit
- Starter for direct starting of the pump
- Thermal relay to protect the pump from overload
- Capacitor connection if required (not included)
- I-0-II selector switch for manual or automatic operation, either by means of a self-locking starting float switch and a separate float switch for stopping, or by means of a start-stop float switch
- manual operation with start-up independent of the level
- Indicating lamps for operation, fault
- Visual and audible overflow alarm with possibility of deactivation
- Connection terminal block with wiring diagram
START-UP PANEL FOR THREE-PHASE WASTEWATER PUMP WITH DOL STARTER CD1D3___
- Plastic watertight cabinet of protection class IP54
- General load switch
- Asymmetry, succession and out-of-phase monitor
- Thermomagnetic switch according to the current drawn by the pump to protect against overload, overcurrent, short circuit
- Starter for direct starting of the pump
- Connection terminals for the internal thermal pump in series with the control circuit
- I-0-II selector switch for selection of manual or automatic operation either by means of a self-locking starting float switch and a separate float switch for stopping, or by means of a start-stop float switch
- manual operation with start-up independent of the level
- Indicator lights for operation, fault, voltage fault
- Visual and audible overflow alarm with possibility of deactivation
- Connection terminal block with wiring diagram
START-UP PANEL FOR WASTEWATER PUMP WITH STARTER CD1Y3___
- Metal watertight cabinet of protection class IP54
- General load switch
- Asymmetry, succession and out-of-phase monitor
- Automatic “D” curve fuses in combination with thermal relay, suitable for motor protection against overcurrent, short circuit and overload or alternatively, thermomagnetic circuit breaker
- H/D starter sized according to the pump power
- Connection terminals for the internal thermal pump in series with the control circuit
- I-0-II selector switch for selection of manual or automatic operation either by means of a self-locking starting float switch and a separate float switch for stopping, or by means of a start-stop float switch
- manual operation with start-up independent of the level
- Indicator lights for operation, fault, voltage fault
- Visual and audible overflow alarm with possibility of deactivation
- Connection terminal block with wiring diagram
| CODE | ADDITIONS |
| F | Free voltage contacts for operation, fault and overflow indication (for CD1D1__ PANELS) |
| Free voltage contacts for operation, fault, voltage fault and overflow indication (for CD1D3__ and CD1Y3__ PANELS) | |
| M | 3-display instrument with voltage transformers |
| P | Protection against dry operation via drilling power factor (cosf) without Autoreset |
| A | 12VDC power supply with battery connection for self-activation of the overflow alarm |
| C | Battery for overflow alarm autonomy 12VDC/3.2Ah |
| Χ | Reinforced universal socket |
- Control and automation panels for starting a wide range of rainwater/wastewater pumps.
- Single pump start-up.
- Protection against dry running of pumps by means of a float switch in the event of drainage of the pumping tank.
- Starting of pumps by means of point level or adjustable differential level float switches with counterbalance.
- Visual and audible alarm of overflow of the pumping tank
| START-UP PANELS FOR 1 RAINWATER/WATER PUMP | ||||||||
| Type | Voltage | Hp | KW | Start-up | Range A | Box material | Protection | Dimensions H x W x D (mm) |
| CD1D1007 | 230V | 1 | 0,75/1,1 | DOL | 4-6 | ABS | IP54 |
400x300x170 |
| CD1D1011 | 1,5 | 1,1/1,2 | 5,5-8 | 400x300x170 | ||||
| CD1D1015 | 2 | 1,5/1,7 | 7-10 | 400x300x170 | ||||
| CD1D1022 | 3 | 2,2 | 9-13 | 400x300x170 | ||||
| CD1D3007 | 400V | 1 | 0,75 | DOL | 1,6-2,5 |
ABS
|
IP54
|
400x300x170 |
| CD1D3011 | 1,5 | 1,1 | 2,5-4 | 400x300x170 | ||||
| CD1D3015 | 2 | 1,5 | 2,5-4 | 400x300x170 | ||||
| CD1D3022 | 3 | 2,2 | 4-6,3 | 400x300x170 | ||||
| CD1D3030 | 4 | 3 | 6-10 | 400x300x170 | ||||
| CD1D3040 | 5,5 | 4 | 6-10 | 400x300x170 | ||||
| CD1Υ3055 | 400V | 7,5 | 5,5 |
Υ/Δ
|
9-14* |
METAL
|
IP54
|
500x400x200 |
| CD1Υ3075 | 10 | 7,5 | 13-18* | 500x400x200 | ||||
| CD1Υ3110 | 15 | 11 | 21-26 | 600x400x200 | ||||
| CD1Υ3150 | 20 | 15 | 20-31 | 600x400x200 | ||||
| CD1Υ3185 | 25 | 18,5 | 30-40 | 700x500x200 | ||||
| CD1Υ3220 | 30 | 22 | 40-47 | 700x500x200 | ||||
| CD1Υ3300 | 40 | 30 | 52-61 | 800x600x200 | ||||
| CD1Υ3370 | 50 | 37 | 65-75 | 800x600x200 | ||||
In the CD1Y3__ series a fuse with a thermal switch is used except for the asterisks where a thermomagnetic fuse is used.
- Construction with CHINT main materials